Quality Control Test Results interface for JD Edwards
About the Quality Control Test Results
This interface compares test results and determines if lots pass quality inspection.
The Quality Control Test Results interface allows the entry of test results at various points in the business cycle. The system compares the results to the minimum and maximum values and the acceptable quantity or percentage that were previously defined for the test. Based on how many samples pass or fail, the system evaluates the lot to determine whether it passes or fails quality inspection. The system then sets the lot status to the value that was defined in the processing option for failed lot status.
This interface calls the BD3N3702 business function to retrieve the processing options from the interactive program, P3711.
Name | Function name | Description |
---|---|---|
DD3N3711 |
dcLINK Interface Quality Control Test Results Data Structure |
|
ND3N3711 |
dcLINKInterfaceQualityControlTes |
dcLINK Interface Quality Control Test Results |
DD3N3702 |
PO Retrievals F3701 Test Revisions Data Structure |
|
BD3N3702 |
PORetrievalCartonReorganization |
PO Retrievals F3701 Test Revisions |
The full name of this interface is ND3N3711 Quality Control Test Results
This interface guide applies to the following JDE versions.
-
EnterpriseOne 8.10
Processing options
Processing options for Quality Control Test Results.
The DreamWriter defaults to ZJDE0001 if not otherwise specified in the parameter list on the call.
Defaults tab
-
Status (cPO_Status_STAW): This field indicates which test definitions to display. Valid values are:
-
Blank - Display only active definitions.
-
1 - Display only test definitions which are pending approval.
-
2 - Display only historical test definitions.
-
3 - Display only rejected change requests.
-
Process tab
-
Log History (cPO_LogHistoryActivated_EV02): This field indicates whether to record the existing test definitions before applying the modifications. Valid values are:
-
Blank - Do not record test definitions before applying the modifications.
-
1 - Record test definitions before applying the modifications.
-
Workflow tab
-
Workflow (cPO_WorkflowActivated_EV01): This field indicates whether to activate workflow approval processing when modifications are made to test definitions. Valid values are:
-
Blank - Workflow approval is not activated.
-
1 - Activate workflow approval.
-
Processing option data structure for DD3N3702
The interface retrieves these parameters by calling BD3N3702. They are passed back in the following data structure.
Type | Description | Parameter |
---|---|---|
String |
szPO_Version_VERS |
Input |
Char |
cPO_Status_STAW |
Output |
Char |
cPO_LogHistoryActivated_EV02 |
Output |
Char |
cPO_WorkflowActivated_EV01 |
Output |
Processing
Processing information for Quality Control Test Results interface.
Processing
The characteristics of an item determine which fields are required by the interface. Some characteristics are set at the item master level, and some are set at the item/branch level. The item/branch level always takes precedence over the item master. Refer to the Special Processing Interface Usage Guide for more information.
Verify the processing
Steps to verify the processing of the Quality Control Test Results interface.
To verify the processing, complete the following steps in JDE.
-
Go to the Quality Management Daily Operations menu (G3711).
-
Select Enter Test Results.
-
On Work With Test Results, select Find.
-
Choose a record and Select to display the records associated with the Lot Serial Number.
Input data structure
Input data structure for DD3N3711.
Name | Default values | R/O | Alias | Notes |
---|---|---|---|---|
cdcLINKActionCode_EV01 |
0 |
X |
EV01 |
The dcLINK Action Code is defaulted to “0”. |
cActionCode_ACTION |
1 |
X |
ACTION |
If not passed in, the Action Code “1” is used. |
jdDateUpdated_UPMJ |
Current Date |
X |
UPMJ |
This field is retrieved from GetAuditInfo. |
mnTimeUpdate_TDAY |
Current Time |
X |
TDAY |
This field is retrieved from GetAuditInfo. |
szUserId_USER |
Current User |
X |
USER |
If this field is not passed in, a value is retrieved from GetAuditInfo. |
szWorkStationId_JOBN |
Current Workstation |
X |
JOBN |
This field is retrieved from GetAuditInfo. |
mnJobNumber_JOBS |
O |
JOBS |
||
szProgramId_PID |
ND3N3711 |
X |
PID |
This field defaults in the program if not passed in. |
szVersion_VERS |
ZJDE0001 |
X |
VERS |
If not passed in, the ZJDE0001 version is used. |
cSuppressErrMsg_EV01 |
O |
EV01 |
||
cErrorCode_ERRC |
X |
ERRC |
This is a returned value. “1” = warning, “2” = error. |
|
szErrorMessageKey_EKEY |
X |
EKEY |
This value is returned and contains the alias of the error message. |
|
iDebugLevel_INT01 |
O |
INT01 |
If this field value is greater than zero, the M&D Debug statements are displayed. |
|
szdcLINKCallingFunction_PID |
O |
PID |
||
mnOrderNumber_DOCO |
R |
DOCO |
||
szOrderType_DCTO |
R |
DCTO |
||
szOrderCompany_KCOO |
C |
KCOO |
If the Quality Application Code is MC, MR, PG, PR, or SO, this field is required. |
|
szOrderSuffix_SFXO |
C |
SFXO |
If the Quality Application Code is MR or PG, this field is required. |
|
mnLineNumber_LNID |
C |
LNID |
If the Quality Application Code is MR, PG, PR, or SO, this field is required. |
|
szBranchPlant_MCU |
R |
MCU |
||
szLot_LOTN |
O |
LOTN |
||
mnIdentifierShortItem_ITM |
O |
ITM |
||
mnAddressNumber_AN8 |
O |
AN8 |
||
szLocation_LOCN |
O |
LOCN |
||
szQualityApplicationCode_QPCD |
R |
QPCD |
This field requires one of the following entries: EC, EO, MC, MN, MO, MR, PG, PR, or SO. |
|
mnTripNumber_TRP |
O |
TRP |
||
mnLogicalCompartmentNumb_LCMP |
O |
LCMP |
||
szVehicleId_VEHI |
O |
VEHI |
||
cPassFailPF_QPF |
O |
QPF |
||
mnSequenceNoOperations_OPSQ |
C |
OPSQ |
If the Quality Application Code is MO, this field is required. |
|
mnOperationsSequence_OPRS |
O |
OPRS |
||
mnBubbleSequence_BSEQ |
O |
BSEQ |
||
szTypeRouting_TRT |
O |
TRT |
||
mnAddressNumberShipTo_SHAN |
O |
SHAN |
||
cQualityTestRequired_QLTR |
O |
QLTR |
||
mnAddressNumberParent_PA8 |
O |
PA8 |
||
szVersion_F3711_VERS |
O |
VERS |
||
szCostCenterTransp_VMCU |
O |
VMCU |
||
jdDateTransaction_TRDJ |
O |
TRDJ |
||
cPreferenceFound_EV01 |
O |
EV01 |
||
cPreferenceCheckYN_EV01 |
O |
EV01 |
||
szWorkCenter_MMCU |
O |
MMCU |
||
mnOrderQuantity_UORG |
O |
UORG |
||
mnTripLegNumber_TRPL |
O |
TRPL |
||
szRegistrationLicenseNo_RLNO |
O |
RLNO |
||
jdLoadDate_LOAD |
O |
LOAD |
||
jdOrderDateRequested_DRQJ |
O |
DRQJ |
||
cMode_EV01 |
O |
EV01 |
||
szResultValue_QVAL |
O |
QVAL |
||
szTestID_QTST |
O |
QTST |
||
mnSample_SNBR |
O |
SNBR |
||
mnTester_ANO |
O |
ANO |
||
jdDateTested_QDAT |
O |
QDAT |
||
szRootCause_QRTC |
O |
QRTC |
||
szDefectSource_QDFC |
O |
QDFC |
||
mnOpeSeq_OPSQ |
O |
OPSQ |
||
cO_TOVR |
O |
TOVR |
||
szProperty_QPRP |
O |
QPRP |
||
szAllowableMinimum_AMIN |
O |
AMIN |
||
szPreferableMinimum_PMIN |
O |
PMIN |
||
szTarget_QTRG |
O |
QTRG |
||
szPreferableMaximum_PMAX |
O |
PMAX |
||
szAllowableMaximum_AMAX |
O |
AMAX |
||
szTestMethod_TMHD |
O |
TMHD |
||
cType_TTTY |
O |
TTTY |
||
szResultUOM_RSUM |
O |
RSUM |
||
szTimeTested_VC08A |
O |
VC08A |
O = Optional
X = Required but will default in if not passed
C = Conditional (see notes for conditions)
Loading...