Fixed Assets Location Transfer interface for JD Edwards
About the Fixed Asset Location Transfer interface
This interface allows users to move a fixed asset from one location to another.
Each time a transfer is made a history record captures where it has been. The dcLINK version is called ND3N1215. This interface was written in NER and calls a ‘C' business function, BD3N1205, to retrieve the processing options from the interactive program P12115.
Name | Function name | Description |
---|---|---|
DD3N1215 |
dcLINK Interface Fixed Asset Location Transfer |
|
ND3N1215 |
dcLINKInterfaceReleaseOrder |
dcLINK Interface Fixed Asset Location Transfer |
DD3N1205 |
PO Retrieval Fixed Asset Location Transfer |
|
BD3N1205 |
PORetrievalFALocationTransfer |
PO Retrieval Fixed Asset Location Transfer |
The full name of this interface is ND3N1215 Fixed Assets Location Transfer
This interface guide applies to the following JDE versions.
-
EnterpriseOne Xe through 9.1
Corresponding EnterpriseOne application
In EnterpriseOne, the application you would run to release orders is P12115. This application can be found on menu G1211. Select the Location Inquiry app and from there the form exit Transfers.
Processing options
Processing options for ND3N1215.
The dream writer version will default to ZJDE0001 if not otherwise specified in the parameter list on the call.
Only three of these processing options are being used in this NER. The cUpdateChildRateCode_EV02 and cUpdateChildBillingAmount_EV03 are passed into the MBF F1204 Transfer Children. The other processing option that is used is cBillingInformation_EV01, which tells the interface if the billing information (business unit, object account, and subsidiary) that had been entered on a previous transfer should copy over when the asset is transferred to a new location. A value of ‘1' tells the system to not clear the billing information; a value of blank clears it.
Processing option data structure for DD3N1205
Our interface retrieves these parameters by calling BD3N1205 and is passed back in the following data structure.
Type | Description | Parameter |
---|---|---|
String |
szVersion_VERS |
Input |
Char |
cDisplayMeters_EV01 |
Output |
Char |
cUpdateChildRateCode_EV02 |
Output |
Char |
cUpdateChildBillingAmount_EV03 |
Output |
String |
szLocationCode_AL |
Output |
String |
szLocation_LOC |
Output |
Char |
cBillingInformation_EV01 |
Output |
String |
szP12215Version_VERS |
Output |
String |
szP12120Version_VERS |
Output |
Processing
Processing information for performing a fixed asset location transfer.
At a minimum, what needs to be supplied to perform a transfer is the asset number, the location to which the asset is being moved, and the time when the transfer is to take place. The “when” can simply be the effective date of the transfer, assuming you are only moving the asset once a day. If the asset could be moved multiple times during the day, then you must also supply the beginning time.
Action codes
Technically this interface has two values for the dcLINKActionCode: a 1 and a 2. The ‘1' tells the interface to perform an asset transfer. The ‘2' tells the interface to do an asset inquiry. The inquiry does not return a list of the locations to which the asset has been transferred, so there is no practical reason to perform an inquiry.
Required fields
In order to perform a transfer, the asset number (mnAssetNumber_NUMB), and the location (szToLocation_MCU) to which the asset is being transferred must be passed in. The effective date (jdEffectiveDate_EFT) may be supplied, but will default to today's date if a value is not supplied.
Verify the processing
Verify the processing of the transfer.
To verify the processing, complete the following steps in JDE.
-
Open menu G1211.
-
Go to the location inquiry application and check the following fields.Step Information
-
The Location to which the asset was just transferred will be marked as the current (C) location.
-
The Begin Date will be the effective date entered on the transfer.
-
The Previous Location will be a history (H) record.
-
The Ending Date will be the effective date entered.
-
Input data structure
Input data structure for DD3N0111.
Name | Default value | R/O | Alias | Notes |
---|---|---|---|---|
cdcLINKActionCode_EV01 |
1 |
X |
EV01 |
1 = Fixed Asset Transfer. 2 = Inquiry only. |
cActionCode_ACTION |
Not used |
X |
ACTION |
|
jdDateUpdated_UPMJ |
Current Date |
X |
UPMJ |
Retrieved from GetAuditInfo. |
mnTimeUpdated_UPMT |
Current Time |
X |
UPMT |
Retrieved from GetAuditInfo. |
szUserId_USER |
Current User |
X |
USER |
Retrieved from GetAuditInfo. |
szWorkStationId_JOBN |
Current Workstation |
X |
JOBN |
Retrieved from GetAuditInfo. |
mnJobNumber_JOBS |
O |
JOBS |
||
szProgramId_PID |
ND3N1215 |
X |
PID |
Defaulted in program if not passed in. |
szVersion_VERS |
ZJDE0001 |
X |
VERS |
Defaulted in program if not passed in. |
cSuppressErrorMessage_EV01 |
O |
EV01 |
||
cErrorCode_ERRC |
Blanks |
X |
ERRC |
Defaulted in program. |
szErrorMessageKey_EKEY |
Blanks |
X |
EKEY |
Defaulted in program. |
iDebugLevel_INT01 |
O |
INT01 |
Displays M&D Debug statements if the value is greater than 0. |
|
szGuidUniqueID_GUID |
Blanks |
O |
GUID |
If generate GUIDs is turned on in the dcLINK configuration utility, this field will contain a GUID (guaranteed unique identifier). The GUID is used to tie database changes in PeopleSoft to the transactions that triggered those changes to occur. |
szGuidApprover1_USR1 |
Blanks |
O |
USR1 |
An entry in this field or the Approver 2 field will cause a signature capture record to be written. Signature capture records are part of the GUID processing and should not be used unless a GUID is being created by dcLINK. The value of this field is a User ID, not an address book entry. There must be a value passed in to either this field or the approver 2 field, otherwise it is an error. |
szGuidFullName1_FULLNAME1 |
Blanks |
O |
FULLNAME1 |
This field is the full name of the GUID Approver 1. |
szGuidApprover2_USR2 |
Blanks |
O |
USR2 |
GUID processing supports up to two approvers. If two approvers are required, this is the user ID of the second approver. There must be a value passed in to either this field, or the approver 1 field, otherwise it is an error. |
szGuidFullName2_FULLNAME2 |
Blanks |
O |
FULLNAME2 |
This field is the full name of the GUID Approver 2. |
mnGuidReasonCode1_REASON1 |
Blanks |
O |
REASON1 |
If either of the approver fields contain a value, but no value is entered into one of the reason code fields, then an error will be returned. Reason codes must match the valid reason codes setup for GUID processing, otherwise it is an error. |
szGuidCommentField_COMMENTS |
Blanks |
O |
COMMENTS |
This is a free form entry field that is used to further explain the reason code entered into the previous field. |
mnGuidReasonCode2_REASON2 |
Blanks |
O |
REASON2 |
If either of the approver fields contains a value, but no value is entered into one of the reason code fields, then an error will be returned. Reason codes must match the valid reason codes setup for GUID processing, otherwise it is an error. |
szGuidCommentField2_2COMMENTS |
Blanks |
O |
2COMMENTS |
This is a free form entry field that is used to further explain the reason code entered in the previous field. |
szGuidScriptID_FMNMVERS |
Blanks |
O |
FMNMVERS |
In PeopleSoft the screen ID where the change was made is captured. dcLINK captures the script ID. |
szGuidTextMessage_TEXTMES |
Blanks |
O |
TEXTMES |
This is a free form entry field. |
mnAssetNumber_NUMB |
R |
NUMB |
If a value is not passed in an error will be returned. |
|
szSerialNumber_ASID |
O |
ASID |
||
szToLocation_MCU |
O |
MCU |
This is a required field if the dcLINKActionCode is equal to a “1” = Transfer. |
|
szFromLocation_MCU |
Current Location |
O |
MCU |
When you make a transfer ,the from location will default to be the location where the asset is currently located. |
jdEffectiveDate_EFT |
Today's date |
O |
EFT |
If this parameter is left blank it will default to today's date. |
szBeginningTime_FTIME |
O |
FTIME |
Enter a beginning time if you are planning on making multiple transfers on a single day. |
|
szTransferNumber_TRNN |
O |
TRNN |
This will be assigned by JDE when a transfer is made. |
|
jdDateEnding_END |
O |
END |
||
szEndTime_FTIME |
O |
FTIME |
||
mnQuantity_QTY |
O |
QTY |
If this is a transfer, this quantity is checked against the current quantity in F1201. If this quantity is greater than what's in the file, an error message is created. |
|
szRemark_RMK |
Blanks |
O |
RMK |
Any value entered into the remark shows up on the transfer log. When I transferred an asset into the SHOP I used the remark to indicate what was wrong with the asset. |
szEquipmentStatus_EQST |
O |
EQST |
Any value entered will be validated against the UDC table 12/ES. |
|
mnBillingAmount_AMTB |
O |
AMTB |
||
szBusinessUnit_MCU |
Blanks |
O |
MCU |
Together with object account and subsidiary, this is used to identify where the billing should go. |
szObjectAccount_OBJ |
Blanks |
O |
OBJ |
Together with business unit and subsidiary, this is used to identify where the billing should go. |
szSubsidiary_SUB |
Blanks |
O |
SUB |
Together with business unit and object account, this is used to identify where the billing should go. |
cSubledgerType_SBLT |
Blanks |
O |
SBLT |
|
szSubledger_SBL |
Blanks |
O |
SBL |
|
cTransferActionCode_ROS |
Blanks |
O |
ROS |
Blanks are valid 1 = Rented to Job 2 = Sold to Job 3 = Bought back from the job 4 = Future Use |
szColumn_AISL |
O |
AISL |
||
szRow_BIN |
O |
BIN |
||
mnMeterReadingCurrent_MTRC |
O |
MTRC |
||
mnMeterReadingOriginal_MTRO |
O |
MTRO |
X = Required but will default in if not passed
O = Optional
Transaction test scenarios
The following test scenarios demonstrate a variety of ways in which this interface could be used, and the fields that would be passed for each scenario.
The data structure fields are in the left column, and the corresponding values for each scenario are listed by column.
Field name | Transfer with just a date | Transfer using time | Transfer with account |
---|---|---|---|
cdcLINKActionCode_EV01 |
1 |
||
cActionCode_ACTION |
|||
jdDateUpdated_UPMJ |
|||
mnTimeUpdated_UPMT |
|||
szUserId_USER |
Elvis |
Elvis |
Elvis |
szWorkStationId_JOBN |
|||
mnJobNumber_JOBS |
|||
szProgramId_PID |
|||
szVersion_VERS |
ZJDE0001 |
ZJDE0001 |
ZJDE0001 |
cSuppressErrorMessage_EV01 |
|||
cErrorCode_ERRC |
|||
szErrorMessageKey_EKEY |
|||
iDebugLevel_INT01 |
|||
szGuidUniqueID_GUID |
|||
szGuidApprover1_USR1 |
|||
szGuidFullName1_FULLNAME1 |
|||
szGuidApprover2_USR2 |
|||
szGuidFullName2_FULLNAME2 |
|||
mnGuidReasonCode1_REASON1 |
|||
szGuidCommentField_COMMENTS |
|||
mnGuidReasonCode2_REASON2 |
|||
szGuidCommentField2_2COMMENTS |
|||
szGuidScriptID_FMNMVERS |
|||
szGuidTextMessage_TEXTMES |
|||
mnAssetNumber_NUMB |
2277 |
2277 |
2277 |
szSerialNumber_ASID |
|||
szToLocation_MCU |
5100 |
SHOP |
5100 |
szFromLocation_MCU |
|||
jdEffectiveDate_EFT |
01/01/2013 |
01/10/2013 |
01/12/2013 |
szBeginningTime_FTIME |
10:00:00 |
||
szTransferNumber_TRNN |
|||
jdDateEnding_END |
|||
szEndTime_FTIME |
|||
mnQuantity_QTY |
|||
szRemark_RMK |
Bent Shaft |
||
szEquipmentStatus_EQST |
|||
mnBillingAmount_AMTB |
|||
szBusinessUnit_MCU |
5100 |
||
szObjectAccount_OBJ |
1355 |
||
szSubsidiary_SUB |
02800 |
||
cSubledgerType_SBLT |
|||
szSubledger_SBL |
|||
cTransferActionCode_ROS |
1 |
||
szColumn_AISL |
|||
szRow_BIN |
|||
mnMeterReadingCurrent_MTRC |
|||
mnMeterReadingOriginal_MTRO |
Common error messages
The following are common error messages that can be generated by this BF, and what those error messages mean.
Error message | Meaning |
---|---|
0002 |
Record Invalid. One way this error can be returned is if GUIDs are being used, and an error is returned from the business function dcLINK Utility Set Audit Info, or the utility dcLINK Utility Write Signature Capture Record. This error can also be returned if you are trying to do a transfer but transfer quantity is being split. |
0626 |
Asset Number Invalid Input. The field mnAssetNumber_NUMB cannot be blank or null. |
069D |
Invalid Location. If dcLINKActionCode_EV01 is equal to a “1” (transfer), then the location filed szToLocation_MCU cannot be blank or null. |
0769 |
Range Invalid. You can transfer an asset on the same date (effective date entered equals effective date in the file), but then the transfer times are compared. If the effective time passed in (mnTimeBeginning_DDTS) is less than the beginning time in the F1204 file, then it's an error. |
078F |
Insert to table failed. Either the insert to the F1204 or the insert to the F1210 failed. |
078H |
Update to table failed An error occurred updating either the F1204, the F1201, or the F1307 table. No update occurred. |
078I |
Fetch from table failed No record was found when we tried to return the current record in the F1204 file for the asset being processed (mnAssetNumber_NUMB). |
2761 |
Quantity Invalid. This error is returned if the quantity passed in (mnQuantity_QTY) is greater than the current quantity in the asset master. |
2776 |
Effective Date Invalid. This error is returned if the effective date passed in (jdEffectiveDate_EFT) is less than the effective date already entered in the F1204 file. |
2867 |
Transfer Invalid. This error is returned if the disposal date (jdDateEnding_END) is less than the effective date (jdEffectiveDate_EFT). |
3090 |
Business Unit Number Invalid as Entered. This error is generated if either the “from location” (szFromLocation_MCU), or the “to location” (szToLocation_MCU), fails the validation done by Get Cost Center Master Information business function. This error can also be raised if the business unit (szBusinessUnit_MCU) is passed in but fails the edit in Get Cost Center Master Information. |
Loading...