Most EPP log events are stored in the PostgreSQL database. Log Settings allows admins to configure the level of logging details for different areas as well as how long the log items/records are retained.
To configure log settings, complete the following steps in EPP.
-
Go to Admin > System Configuration > Logging.
-
On the Levels tab, for each area that can be logged, complete one of the following actions.
-
To log high level information about events, select Normal.
-
To log detailed information about events for debugging purposes, select Detail
Expected ResultResult: Log events are saved in the database and can be exported to a zip file in the EPP logs folder. Each log record includes a minimum of a date/time stamp and event ID. -
-
Under Number of Days to Retain, set the number of days you want the log events to be stored.
-
Under Max Number of Logs to Retain, set the maximum number of log events you want to keep.Step InformationNote:The number of days and max number of logs are not mutually exclusive, but will purge based on the first one to be reached.
-
On the Enhancement Engine Purge tab, under Maximum Successful Logs to Retain, enter the number of successful logs you want to retain.
-
Under Maximum Failure Logs to Retain, enter the maximum number of failure logs you want to retain.
-
Under Number of Days to Retain Successful Logs, enter the number of days to retain successful logs.
-
Under Number of Days to Retain Failure Logs, enter the number of days to retain failure logs.
-
Optional. To permanently turn on logging for label template and data dictionary changes, on the Audit Log tab, select Log changes to labels and dictionaries.Step InformationImportant:Once turned on, auditing cannot be turned off.
-
Select Save.